Suitable for accelerated salt spray corrosion test of protective coating of metallic material, automotive  parts  and components,  electric parts  and components, industrial products, etc. Can be used for all kinds of salt spray corrosion tests according to the standards of GB10587-89, GB2423.17-93 "The Basic Environmental Test Regulations of Electric & Electronic Products: Salt Spray Test Method" GB/T10125-1997 as well as equivalent IEC, DIN, MIL and ASTM.
 
 
Technical Specification
 

Standard chambers

 

S120s

S450s

S1000s

S2000s

Plus chambers

 

S120+

S450+

S1000+

S2000+

Champers

 

S120xp

S450xp

S1000xp

S2000xp

Chamber capacity

 

120ltr/4.2cu.ft

450ltr/15.8cu.ft

1000ltr/35.3cu.ft

2000ltr/70.6cu.ft

Mounting format

 

Bench top

Floor standing

Floor standing

Floor standing

Loading threshold

 

250mm/11”

800mm/31.5”

800mm/31.5”

800mm/31.5”

Chamber external dimensions, max

W

1315mm/51.8”

1660mm/65.4”

2025mm/80.0”

2885mm/113.6”

 

D

680mm/26.8”

840mm/33.1”

1205mm/47.5”

1205mm/47.5”

 

H

800mm/31.5”

1510mm/59.5”

1720mm/67.5”

1720mm/67.5”

Chamber internal dimensions, max

W

715mm/28.2”

1010mm/39.5”

1300mm/51.2”

2160mm/85.0”

 

D

490mm/19.3”

640mm/25.0”

980mm/38.5”

980mm/38.5”

 

H

490mm/19.3”

1140mm/45.0”

1320mm/52.0”

1320mm/52.0”

Salt solution reservoir ext. dimensions

W

n/a (integral)

330mm/13.0”

330mm/13.0”

330mm/13.0”

 

D

n/a (integral)

620mm/24.5”

620mm/24.5”

620mm/24.5”

 

H

n/a (integral)

700mm/27.5”

700mm/27.5”

700mm/27.5”

Salt solution reservoir capacity

 

40ltrs/10.5USgal

100ltrs/26USgal

140ltrs/37USgal

140ltrs/37USgal

Removable slotted sample racks

 

4racks each with 24 angled slots

6racks each with 28 angled slot

8racks each with
46 angled slots

16racks each with 46 angled slots

Chamber construction

Glass reinforced plastic, Polyproplyene & PVC parts.

Color

White & light gray with a striking turquoise canopy

Temperature range

Adjustable from ambient to +50oC/+122oF

Salt spray fall – out rates

Adjustable from 0.5 to 3.0ml per 80cm2 per hour

Standard models

 

1 phase

1 phase

1 phase

1 phase

Plus & Premium models

 

1 phase

1 phase

1 phase

1 phase

 

Voltage (VAC) and frequency (Hz) dependant on country/region of installation Deionised/distilled for topping up air saturator and making salt solution. As standard, air saturator is topped up automatically and requires a continuous water connection 0.5 – 6.0 bar (7.3 – 87 psi). if air saturator is topped up manually, option ACC66 must be ordered clean dry & oil free, 4.0 to 6.0 bar (58 – 87psi) with 75ltrs (2.6cu.ft) per minute flow 3m (10ft) exhaust pipe is provided with should be terminated outside building 3m (10ft) drain pipe provided which should be terminated into floor level drain +5 to +30oC (+41 to 86oF), 85% max RH (non – condensing) ambient.